RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/rg.287075154
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chang, K. J.
Right arrow Articles by Bluemke, D. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chang, K. J.
Right arrow Articles by Bluemke, D. A.
Related Collections
Right arrow Magnetic Resonance Imaging
Right arrow Gastrointestinal Radiology
RadioGraphics 2008;28:1983-1998
© RSNA, 2008


EDUCATION EXHIBIT

3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T1

Kevin J. Chang, MD, Ihab R. Kamel, MD, PhD, Katarzyna J. Macura, MD, PhD, and David A. Bluemke, MD, PhD

1 From the Department of Diagnostic Imaging, Rhode Island Hospital and The Miriam Hospital, Warren Alpert Medical School of Brown University, 593 Eddy St, Providence, RI 02903. Presented as an education exhibit at the 2006 RSNA Annual Meeting. Received July 5, 2007; revision requested October 3 and received March 27, 2008; accepted March 31. All authors have no financial relationships to disclose. Address correspondence to K.J.C. (e-mail: kchang{at}lifespan.org).

Three-tesla magnetic resonance (MR) imaging offers substantially higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than 1.5-T MR imaging does, which can be used to improve image resolution and shorten imaging time. Because of these increases in SNR and CNR, as well as changes in T1 and T2 relaxation times, an increase in magnetic susceptibility, and an increase in chemical shift effect, many abdominal applications can benefit from 3.0-T imaging. Increased CNR obtained with a gadolinium-based contrast agent improves lesion conspicuity, requires less intravenous contrast material, and improves MR angiography by increasing spatial and temporal resolution. Increased SNR improves fluid conspicuity and resolution for applications such as MR cholangiopancreatography. Increased chemical shift effect also improves spectral resolution for MR spectroscopy. Several potential problems remain for abdominal imaging at 3.0 T. Limitations on energy deposition may require compromises in pulse sequence timing and flip angles. These compromises result in prolonged imaging time and altered image contrast. Magnetic susceptibility and chemical shift artifacts are worsened, but they may be counteracted by shortening echo time, performing parallel imaging, and increasing bandwidth. Radiofrequency field inhomogeneity is also a major concern in imaging larger fields of view and often leads to standing wave effects and large local variations in signal intensity. Many issues related to MR device compatibility and safety have yet to be addressed at 3.0 T. A 3.0-T MR imaging system has a higher initial cost and a higher cost of upkeep than a 1.5-T system does.

© RSNA, 2008







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOGRAPHICS RADIOLOGY RSNA JOURNALS ONLINE
Copyright © 2008 by the Radiological Society of North America.