RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/rg.275075023
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Akisik, F. M.
Right arrow Articles by Lall, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Akisik, F. M.
Right arrow Articles by Lall, C.
Related Collections
Right arrow Gastrointestinal Radiology
Right arrow Magnetic Resonance Imaging
Right arrowRelated Articles
RadioGraphics 2007;27:1433-1444
© RSNA, 2007


EDUCATION EXHIBIT

Abdominal MR Imaging at 3.0 T1

Fatih M. Akisik, MD, Kumaresan Sandrasegaran, MD, Alex M. Aisen, MD, Chen Lin, PhD, and Chandana Lall, MD

1 From the Department of Radiology, Indiana University School of Medicine, 550 N University Blvd, Suite UH 0279, Indianapolis, IN 46202. Presented as an education exhibit at the 2006 RSNA Annual Meeting. Received February 12, 2007; revision requested April 12 and received May 14; accepted May 22. F.M.A. is a consultant with Repligen and the Bracco Group, K.S. received a grant from Koninklijke Philips Electronics, and A.M.A. is a consultant with Repligen and Algotec Systems; all remaining authors have no financial relationships to disclose. Address correspondence to K.S. (e-mail: ksandras{at}iupui.edu).

Magnetic resonance (MR) imaging at 3.0 T offers an improved signal-to-noise ratio compared with that at 1.5 T. However, the physics of high field strength also brings disadvantages, such as increases in the specific absorption rate, in magnetic field inhomogeneity effects, and in susceptibility artifacts. The use of 3.0-T MR imaging for abdominal evaluations, in particular, has lagged behind that for other applications because of the difficulty of imaging a large volume while compensating for respiratory motion. At a minimum, abdominal MR imaging at 3.0 T requires modifications in the pulse sequences used at 1.5 T. Such modifications may include a decrease in the flip angle used for refocusing pulses and an increase in the repetition time for T1-weighted acquisitions. In addition, parallel imaging and other techniques (hyper-echo sequences, transition between pseudo steady states) may be used to maintain a high signal-to-noise ratio while decreasing acquisition time and minimizing the occurrence of artifacts on abdominal MR images.

© RSNA, 2007


Related Articles

Body MR Imaging at 3.0 T: Understanding the Opportunities and Challenges
Mara M. Barth, Martin P. Smith, Ivan Pedrosa, Robert E. Lenkinski, and Neil M. Rofsky
RadioGraphics 2007 27: 1445-1462. [Abstract] [Full Text] [PDF]

Invited Commentary
Scott I. Sher
RadioGraphics 2007 27: 1462-1464. [Full Text] [PDF]



This article has been cited by other articles:


Home page
RadioGraphicsHome page
J.-Y. Choi, M.-J. Kim, Y. E. Chung, J. Y. Kim, A. C Jones, J. de Becker, and M. van Cauteren
Abdominal Applications of 3.0-T MR Imaging: Comparative Review versus a 1.5-T System
RadioGraphics, July 1, 2008; 28(4): e30 - e30.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
S. I. Sher
Invited Commentary
RadioGraphics, September 1, 2007; 27(5): 1462 - 1464.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOGRAPHICS RADIOLOGY RSNA JOURNALS ONLINE
Copyright © 2007 by the Radiological Society of North America.