RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/rg.243035126
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME Test (opens in a new window)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tomandl, B. F.
Right arrow Articles by Hastreiter, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tomandl, B. F.
Right arrow Articles by Hastreiter, P.
Related Collections
Right arrow Neuroradiology
RadioGraphics 2004;24:637-655
© RSNA, 2004


EDUCATION EXHIBIT

CT Angiography of Intracranial Aneurysms: A Focus on Postprocessing1

Bernd F. Tomandl, MD, Niels C. Köstner, Miriam Schempershofe, Walter J. Huk, MD, Christian Strauss, MD, Lars Anker, MD and Peter Hastreiter, PhD

1 From the Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, D-91054 Erlangen, Germany. Presented as an education exhibit at the 2002 RSNA scientific assembly. Received May 5, 2003; revision requested June 13 and received July 30; accepted July 31. All authors have no financial relationships to disclose. Address correspondence to B.F.T. (e-mail: tomandl@neuroradiologie-erlangen.de).

Computed tomographic (CT) angiography is a well-known tool for detection of intracranial aneurysms and the planning of therapeutic intervention. Despite a wealth of existing studies and an increase in image quality due to use of multisection CT and increasingly sophisticated postprocessing tools such as direct volume rendering, CT angiography has still not replaced digital subtraction angiography as the standard of reference for detection of intracranial aneurysms. One reason may be that CT angiography is still not a uniformly standardized method, particularly with regard to image postprocessing. Several methods for two- and three-dimensional visualization can be used: multiplanar reformation, maximum intensity projection, shaded surface display, and direct volume rendering. Pitfalls of CT angiography include lack of visibility of small arteries, difficulty differentiating the infundibular dilatation at the origin of an artery from an aneurysm, the kissing vessel artifact, demonstration of venous structures that can simulate aneurysms, inability to identify thrombosis and calcification on three-dimensional images, and beam hardening artifacts produced by aneurysm clips. Finally, an algorithm for the safe and useful application of CT angiography in patients with subarachnoid hemorrhage has been developed, which takes into account the varying quality of equipment and software at different imaging centers.

© RSNA, 2004

Index Terms: Aneurysm, CT, 17.12116, 17.73 • Aneurysm, intracranial, 17.73 • Computed tomography (CT), angiography, 17.12116 • Computed tomography (CT), image processing, 17.12117




This article has been cited by other articles:


Home page
RadiologyHome page
Q. Li, F. Lv, Y. Li, T. Luo, K. Li, and P. Xie
Evaluation of 64-Section CT Angiography for Detection and Treatment Planning of Intracranial Aneurysms by Using DSA and Surgical Findings
Radiology, June 9, 2009; (2009) 2523081911.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
J.E. Delgado Almandoz, P.W. Schaefer, N.P. Forero, J.R. Falla, R.G. Gonzalez, and J.M. Romero
Diagnostic Accuracy and Yield of Multidetector CT Angiography in the Evaluation of Spontaneous Intraparenchymal Cerebral Hemorrhage
AJNR Am. J. Neuroradiol., June 1, 2009; 30(6): 1213 - 1221.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Romijn, H.A.F. G. van Andel, M.A. van Walderveen, M.E. Sprengers, J.C. van Rijn, W.J. van Rooij, H.W. Venema, C.A. Grimbergen, G.J. den Heeten, and C.B. Majoie
Diagnostic Accuracy of CT Angiography with Matched Mask Bone Elimination for Detection of Intracranial Aneurysms: Comparison with Digital Subtraction Angiography and 3D Rotational Angiography
AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 134 - 139.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
Q. Liu, J. P. Lu, F. Wang, L. Wang, and J. M. Tian
Three-dimensional Contrast-enhanced MR Angiography of Aortic Dissection: A Pictorial Essay
RadioGraphics, September 1, 2007; 27(5): 1311 - 1321.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. H. Rodallec, A. Krainik, A. Feydy, A. Helias, J.-M. Colombani, M.-C. Julles, V. Marteau, and M. Zins
Cerebral Venous Thrombosis and Multidetector CT Angiography: Tips and Tricks
RadioGraphics, October 1, 2006; 26(suppl_1): S5 - S18.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. M. Lell, K. Anders, M. Uder, E. Klotz, H. Ditt, F. Vega-Higuera, T. Boskamp, W. A. Bautz, and B. F. Tomandl
New Techniques in CT Angiography
RadioGraphics, October 1, 2006; 26(suppl_1): S45 - S62.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
B.F. Tomandl, T. Hammen, E. Klotz, H. Ditt, B. Stemper, and M. Lell
Bone-Subtraction CT Angiography for the Evaluation of Intracranial Aneurysms
AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 55 - 59.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Takhtani
CT Neuroangiography: A Glance at the Common Pitfalls and Their Prevention
Am. J. Roentgenol., September 1, 2005; 185(3): 772 - 783.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOGRAPHICS RADIOLOGY RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.