RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/rg.23si035514
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME Test (opens in a new window)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pannu, H. K.
Right arrow Articles by Fishman, E. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pannu, H. K.
Right arrow Articles by Fishman, E. K.
Related Collections
Right arrow Cardiac Radiology
Right arrow Computed Tomography
(Radiographics. 2003;23:S111-S125.)
© RSNA, 2003


IMAGING OF THE CORONARY ARTERY

Current Concepts in Multi–Detector Row CT Evaluation of the Coronary Arteries: Principles, Techniques, and Anatomy1

Harpreet K. Pannu, MD, Thomas G. Flohr, PhD, Frank M. Corl, MS and Elliot K. Fishman, MD

1 From the Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institutions, Baltimore, Md (H.K.P., F.M.C., E.K.F.); and the CT Division, Siemens Medical Solutions, Forchheim, Germany (T.G.F.). Presented as an education exhibit at the 2002 RSNA scientific assembly. Received March 5, 2003; revision requested April 16 and received May 21; accepted May 29. T.G.F. is an employee of Siemens Medical Solutions. E.K.F. is a consultant to the CT Advisory Board. Address correspondence to H.K.P., Department of Radiology, Johns Hopkins Hospital, 600 N Wolfe St, Baltimore, MD 21287 (e-mail: hpannu1@jhmi.edu).

Cardiac imaging is becoming a practical application of mechanical computed tomography (CT) with the availability of four, eight, and 16 detector row scanners. The role of imaging is progressing from simple determination of the presence of arterial calcifications on nonenhanced scans to demonstration of vascular stenoses on coronary CT angiograms. Optimization of the imaging technique and knowledge of coronary artery anatomy are both important for the development of CT of the heart. Technical factors such as a slow heart rate, a short scanning time, subcentimeter spatial resolution, high temporal resolution, and reconstruction of multiple image data sets at various intervals in the cardiac cycle result in optimal visualization of the coronary arteries. Axial, thin-slab maximum intensity projection, and volume-rendered images are used to display the normal anatomy and anomalies of the coronary arteries. The challenges of CT angiography of the coronary arteries have been partially met and will likely be overcome with continued evolution of the technology.

© RSNA, 2003

Index Terms: Computed tomography (CT), angiography, 54.12116 • Computed tomography (CT), multi–detector row, 54.12116 • Coronary vessels, CT, 54.12116 • Coronary vessels, stenosis or obstruction, 54.76




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
I-C. Tsai, W.-L. Lee, C.-R. Tsao, Y. Chang, M.-C. Chen, T. Lee, and W.-C. Liao
Comprehensive Evaluation of Ischemic Heart Disease Using MDCT
Am. J. Roentgenol., July 1, 2008; 191(1): 64 - 72.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. N. Shetty, K. G. Bis, A. R. Vyas, A. Kumar, A. Anderson, and M. Balasubramaniam
Contrast Volume Reduction with Superior Vena Cava Catheter-Directed Coronary CT Angiography: Comparison with Peripheral IV Contrast Enhancement in a Swine Model
Am. J. Roentgenol., April 1, 2008; 190(4): W247 - W254.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard
Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity
Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. Mahesh and D. D. Cody
AAPM/RSNA Physics Tutorial for Residents: Physics of Cardiac Imaging with Multiple-Row Detector CT
RadioGraphics, September 1, 2007; 27(5): 1495 - 1509.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Hur, S. W. Hong, S. Y. Kim, Y. H. Kim, Y. J. Hwang, W. R. Lee, and S. J. Cha
Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography
Am. J. Roentgenol., July 1, 2007; 189(1): 188 - 196.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Ferencik, D. Ropers, S. Abbara, R. C. Cury, U. Hoffmann, K. Nieman, T. J. Brady, F. Moselewski, W. G. Daniel, and S. Achenbach
Diagnostic Accuracy of Image Postprocessing Methods for the Detection of Coronary Artery Stenoses by Using Multidetector CT
Radiology, June 1, 2007; 243(3): 696 - 702.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Kumar, K. G. Bis, A. Shetty, A. Vyas, A. Anderson, M. Balasubramaniam, W. O'Neill, and W. Stein
Aortic Root Catheter-Directed Coronary CT Angiography in Swine: Coronary Enhancement with Minimum Volume of Iodinated Contrast Material
Am. J. Roentgenol., May 1, 2007; 188(5): W415 - W422.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, S. Attaran, A. Chow, S. Purkayastha, and A. Darzi
Multi-slice computed tomography in coronary artery disease.
Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 443 - 450.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
S. Y. Kim, J. B. Seo, K.-H. Do, J.-N. Heo, J. S. Lee, J.-W. Song, Y. H. Choe, T. H. Kim, H. S. Yong, S. I. Choi, et al.
Coronary Artery Anomalies: Classification and ECG-gated Multi-Detector Row CT Findings with Angiographic Correlation.
RadioGraphics, March 1, 2006; 26(2): 317 - 333.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. F. Bruzzi, M. Remy-Jardin, D. Delhaye, A. Teisseire, C. Khalil, and J. Remy
When, Why, and How to Examine the Heart During Thoracic CT: Part 1, Basic Principles
Am. J. Roentgenol., February 1, 2006; 186(2): 324 - 332.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
M. H. K. Hoffmann, H. Shi, B. L. Schmitz, F. T. Schmid, M. Lieberknecht, R. Schulze, B. Ludwig, U. Kroschel, N. Jahnke, W. Haerer, et al.
Noninvasive Coronary Angiography With Multislice Computed Tomography
JAMA, May 25, 2005; 293(20): 2471 - 2478.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
T. Nakanishi, Y. Kayashima, R. Inoue, K. Sumii, and Y. Gomyo
Pitfalls in 16-Detector Row CT of the Coronary Arteries
RadioGraphics, March 1, 2005; 25(2): 425 - 438.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOGRAPHICS RADIOLOGY RSNA JOURNALS ONLINE
Copyright © 2003 by the Radiological Society of North America.