|
|
||||||||
IMAGING OF THE CORONARY ARTERY |
1 From the Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institutions, Baltimore, Md (H.K.P., F.M.C., E.K.F.); and the CT Division, Siemens Medical Solutions, Forchheim, Germany (T.G.F.). Presented as an education exhibit at the 2002 RSNA scientific assembly. Received March 5, 2003; revision requested April 16 and received May 21; accepted May 29. T.G.F. is an employee of Siemens Medical Solutions. E.K.F. is a consultant to the CT Advisory Board. Address correspondence to H.K.P., Department of Radiology, Johns Hopkins Hospital, 600 N Wolfe St, Baltimore, MD 21287 (e-mail: hpannu1@jhmi.edu).
Cardiac imaging is becoming a practical application of mechanical computed tomography (CT) with the availability of four, eight, and 16 detector row scanners. The role of imaging is progressing from simple determination of the presence of arterial calcifications on nonenhanced scans to demonstration of vascular stenoses on coronary CT angiograms. Optimization of the imaging technique and knowledge of coronary artery anatomy are both important for the development of CT of the heart. Technical factors such as a slow heart rate, a short scanning time, subcentimeter spatial resolution, high temporal resolution, and reconstruction of multiple image data sets at various intervals in the cardiac cycle result in optimal visualization of the coronary arteries. Axial, thin-slab maximum intensity projection, and volume-rendered images are used to display the normal anatomy and anomalies of the coronary arteries. The challenges of CT angiography of the coronary arteries have been partially met and will likely be overcome with continued evolution of the technology.
© RSNA, 2003
Index Terms: Computed tomography (CT), angiography, 54.12116 Computed tomography (CT), multidetector row, 54.12116 Coronary vessels, CT, 54.12116 Coronary vessels, stenosis or obstruction, 54.76
This article has been cited by other articles:
![]() |
I-C. Tsai, W.-L. Lee, C.-R. Tsao, Y. Chang, M.-C. Chen, T. Lee, and W.-C. Liao Comprehensive Evaluation of Ischemic Heart Disease Using MDCT Am. J. Roentgenol., July 1, 2008; 191(1): 64 - 72. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. N. Shetty, K. G. Bis, A. R. Vyas, A. Kumar, A. Anderson, and M. Balasubramaniam Contrast Volume Reduction with Superior Vena Cava Catheter-Directed Coronary CT Angiography: Comparison with Peripheral IV Contrast Enhancement in a Swine Model Am. J. Roentgenol., April 1, 2008; 190(4): W247 - W254. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Mahesh and D. D. Cody AAPM/RSNA Physics Tutorial for Residents: Physics of Cardiac Imaging with Multiple-Row Detector CT RadioGraphics, September 1, 2007; 27(5): 1495 - 1509. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Hur, S. W. Hong, S. Y. Kim, Y. H. Kim, Y. J. Hwang, W. R. Lee, and S. J. Cha Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography Am. J. Roentgenol., July 1, 2007; 189(1): 188 - 196. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ferencik, D. Ropers, S. Abbara, R. C. Cury, U. Hoffmann, K. Nieman, T. J. Brady, F. Moselewski, W. G. Daniel, and S. Achenbach Diagnostic Accuracy of Image Postprocessing Methods for the Detection of Coronary Artery Stenoses by Using Multidetector CT Radiology, June 1, 2007; 243(3): 696 - 702. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kumar, K. G. Bis, A. Shetty, A. Vyas, A. Anderson, M. Balasubramaniam, W. O'Neill, and W. Stein Aortic Root Catheter-Directed Coronary CT Angiography in Swine: Coronary Enhancement with Minimum Volume of Iodinated Contrast Material Am. J. Roentgenol., May 1, 2007; 188(5): W415 - W422. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, S. Attaran, A. Chow, S. Purkayastha, and A. Darzi Multi-slice computed tomography in coronary artery disease. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 443 - 450. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Y. Kim, J. B. Seo, K.-H. Do, J.-N. Heo, J. S. Lee, J.-W. Song, Y. H. Choe, T. H. Kim, H. S. Yong, S. I. Choi, et al. Coronary Artery Anomalies: Classification and ECG-gated Multi-Detector Row CT Findings with Angiographic Correlation. RadioGraphics, March 1, 2006; 26(2): 317 - 333. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Bruzzi, M. Remy-Jardin, D. Delhaye, A. Teisseire, C. Khalil, and J. Remy When, Why, and How to Examine the Heart During Thoracic CT: Part 1, Basic Principles Am. J. Roentgenol., February 1, 2006; 186(2): 324 - 332. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. K. Hoffmann, H. Shi, B. L. Schmitz, F. T. Schmid, M. Lieberknecht, R. Schulze, B. Ludwig, U. Kroschel, N. Jahnke, W. Haerer, et al. Noninvasive Coronary Angiography With Multislice Computed Tomography JAMA, May 25, 2005; 293(20): 2471 - 2478. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Nakanishi, Y. Kayashima, R. Inoue, K. Sumii, and Y. Gomyo Pitfalls in 16-Detector Row CT of the Coronary Arteries RadioGraphics, March 1, 2005; 25(2): 425 - 438. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOGRAPHICS | RADIOLOGY | RSNA JOURNALS ONLINE |