1 From the Department of Diagnostic Radiology, Mayo Clinic and Foundation, 200 First St SW, 2-103 Charlton Bldg, Rochester, MN 55905. Recipient of a Certificate of Merit award for a scientific exhibit at the 1999 RSNA scientific assembly. Received March 27, 2000; revision requested June 21 and received August 9; accepted August 16. Address correspondence to D.S.G. (e-mail: groth.debra@mayo.edu).
The use of picture archiving and communication systems (PACS) and primary soft-copy interpretation in radiology is growing rapidly. The authors present a cathode ray tube (CRT) acceptance test and quality control (QC) program developed over a 5-year period on the basis of experience with multiple PACS and CRT vendors. The CRT QC procedures address monitor cleanliness and setup, qualitative image quality, and quantitative luminance and color measurements. Required materials include a photometer with luminance and color probes and 100%-video, flat-field window and test images from the Society of Motion Picture Test Engineers (SMPTE). Luminance was found to change over time for all gray-scale CRTs examined, which necessitated quarterly recalibration. The phosphor color of these monitors was also found to change, but changes were consistent and slow enough to warrant only annual measurements. Color measurements were found to be especially useful at initial setup and for CRT replacement. Use of this program allowed standardization of absolute luminance of individual CRTs, matching of phosphor color for multimonitor workstations, and systematic tracking of image artifacts. Implementation of a QC program is strongly recommended owing to the dynamic nature of CRT displays.
Index Terms: Cathode ray tubes Images, display Images, quality Images, storage and retrieval Picture archiving and communication system (PACS)
This article has been cited by other articles:
![]() |
D S Brettle and S E Bacon A method for verified access when using soft copy display Br. J. Radiol., August 1, 2005; 78(932): 749 - 751. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-Y. Choi, J.-G. Im, H. J. Lee, M. J. Chung, D. Han, S. H. Park, J. H. Kim, and S.-H. Nam Effect of Monitor Luminance and Ambient Light on Observer Performance in Soft-Copy Reading of Digital Chest Radiographs Radiology, September 1, 2004; 232(3): 762 - 766. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Fuchsjager, C. M. Schaefer-Prokop, E. Eisenhuber, P. Homolka, M. Weber, M. A. Funovics, and M. Prokop Impact of Ambient Light and Window Settings on the Detectability of Catheters on Soft-Copy Display of Chest Radiographs at Bedside Am. J. Roentgenol., November 1, 2003; 181(5): 1415 - 1421. [Abstract] [Full Text] [PDF] |
||||
![]() |
S E Jervis and D S Brettle A practical approach to soft-copy display consistency for PC-based review workstations Br. J. Radiol., September 1, 2003; 76(909): 648 - 652. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOGRAPHICS | RADIOLOGY | RSNA JOURNALS ONLINE |