RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carr, J. J.
Right arrow Articles by Chen, M. Y. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Carr, J. J.
Right arrow Articles by Chen, M. Y. M.
Related Collections
Right arrow Breast (Imaging and Interventional)
(Radiographics. 2001;21:463-473.)
© RSNA, 2001


EDUCATION EXHIBIT

Stereotactic Localization of Breast Lesions: How It Works and Methods to Improve Accuracy1

J. Jeffrey Carr, MD, Paul F. Hemler, PhD, Price W. Halford, MD, Rita I. Freimanis, MD, Robert H. Choplin, MD and Michael Y. M. Chen, MD

1 From the Department of Radiology, Wake Forest University School of Medicine, Medical Center Blvd, Winston-Salem, NC 27157-1088 (J.J.C., P.F.H., P.W.H., R.I.F., M.Y.M.C.); and the Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia (R.H.C.). Received March 8, 2000; revision requested April 26 and received May 18; accepted May 19. Address correspondence to J.J.C. (e-mail: jcarr@wfubmc.edu).

A computer simulation of stereotactic breast biopsy was developed that paralleled the geometric configuration of a currently available breast biopsy system. This model was developed to define and improve the targeting of breast lesions with stereotactic biopsy techniques. Lesions must be clearly identified and accurately targeted on both views for successful localization. Nonvisualization of a lesion may result from overlying tissue or from the geometric configuration of the imaging system. Familiarity with the geometric configuration of the biopsy unit, especially the location of the reference point and center of rotation, facilitates understanding of apparent changes in lesion position (parallax shift). Inaccuracy in lesion targeting on one or both views will manifest predominantly as an error in the calculated z value (depth). The magnitude and direction of this error are largely determined by the direction of the targeting error. Compensatory strategies include use of a long-throw core biopsy gun or directional vacuum-assisted biopsy device and additional sampling along the z axis and should be accompanied by critical evaluation of both pre- and postfire images. Understanding geometric considerations as well as how targeting accuracy affects accuracy in lesion localization should lead to greater success in sampling even challenging breast lesions at stereotactic biopsy.

Index Terms: Biopsies, 00.1261 • Breast, biopsy, 00.1261 • Breast neoplasms, localization, 00.1261 • Computers, simulation • Stereotaxis, 00.1267