RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McCollough, C. H.
Right arrow Articles by Zink, F. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McCollough, C. H.
Right arrow Articles by Zink, F. E.
Related Collections
Right arrow Physics and Basic Science
Right arrow Computed Tomography
(Radiographics. 2000;20:1675-1681.)
© RSNA, 2000


SCIENTIFIC EXHIBIT

Motion Artifacts in Subsecond Conventional CT and Electron-Beam CT: Pictorial Demonstration of Temporal Resolution1

Cynthia H. McCollough, PhD, Michael R. Bruesewitz, RT(R), Timothy R. Daly, RT(R) and Frank E. Zink, PhD

1 From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905. Recipient of a Certificate of Merit award for a scientific exhibit at the 1999 RSNA scientific assembly. Received February 25, 2000; revision requested April 24 and received June 19; accepted June 19. Address correspondence to C.H.M. (e-mail: mccollough.cynthia@mayo.edu).

To visually demonstrate the effective temporal resolution of subsecond conventional (slip-ring) and electron-beam computed tomographic (CT) systems, two phantoms containing high-contrast test objects were scanned with a slip-ring CT system (effective exposure time, 0.5 second) and an electron-beam CT system (exposure time, 0.1 second). Images were acquired of each phantom at rest, during translation along the x axis at speeds of 10–100 mm/sec, and during rotation about isocenter at speeds of 0.1 and 0.5 revolution per second. Motion artifacts and loss of spatial resolution were judged to be absent, noticeable, or severe. For 0.5-second conventional CT images, motion artifacts and loss of spatial resolution were noticeable at 10 mm/sec and 0.1 revolution per second and were severe at speeds greater than or equal to 20 mm/sec and at 0.5 revolution per second. For 0.1-second electron-beam CT scans, noticeable, but not severe, motion artifacts and loss of spatial resolution occurred at speeds between 40 and 100 mm/sec and at 0.5 revolution per second. Over the range of physiologic speeds examined, the images provide visually compelling evidence of the effect of improving temporal resolution in CT.

Index Terms: Computed tomography (CT), artifact • Computed tomography (CT), electron beam • Computed tomography (CT), image quality • Phantoms • Test objects




This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
R. Popilock, K. Sandrasagaren, L. Harris, and K. A. Kaser
CT Artifact Recognition for the Nuclear Technologist
J. Nucl. Med. Technol., June 1, 2008; 36(2): 79 - 81.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Grosjean, B. Sauer, R. M. Guerra, M. Daudon, A. Blum, J. Felblinger, and J. Hubert
Characterization of Human Renal Stones with MDCT: Advantage of Dual Energy and Limitations Due to Respiratory Motion
Am. J. Roentgenol., March 1, 2008; 190(3): 720 - 728.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. Liu, C. Cuevas, A. A. Moss, O. Kolokythas, T. J. Dubinsky, and P. E. Kinahan
Gas Bubble Motion Artifact in MDCT
Am. J. Roentgenol., February 1, 2008; 190(2): 294 - 299.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
H. S. Choi, B. W. Choi, K. O. Choe, D. Choi, K.-J. Yoo, M.-I. Kim, and J. Kim
Pitfalls, Artifacts, and Remedies in Multi- Detector Row CT Coronary Angiography
RadioGraphics, May 1, 2004; 24(3): 787 - 800.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOGRAPHICS RADIOLOGY RSNA JOURNALS ONLINE
Copyright © 2000 by the Radiological Society of North America.