RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kundel, H. L.
Right arrow Articles by Nodine, C. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kundel, H. L.
Right arrow Articles by Nodine, C. F.
Related Collections
Right arrow Breast (Imaging and Interventional)
Right arrow Physics and Basic Science
(Radiographics. 1999;19:1313-1318.)
© RSNA, 1999


infoRAD

A Perceptually Tempered Display for Digital Mammograms1

Harold L. Kundel, MD , Susan P. Weinstein, MD , Emily F. Conant, MD , Lawrence C. Toto, BS and Calvin F. Nodine, PhD

1 From the Pendergrass Diagnostic Research Laboratory, Department of Radiology, University of Pennsylvania Medical Center, 308 Stemmler Hall, 3600 Hamilton Walk, Philadelphia, PA 19104. Recipient of a Certificate of Merit award for an infoRAD exhibit at the 1998 RSNA scientific assembly. Received April 9, 1999; revision requested May 12 and received June 10; accepted June 21. Supported by grants DAMD17-96-1-6153 and DAMD17-97-1-7130 from the U.S. Army Medical Research and Materiel Command. Address reprint requests to H.L.K.

The cathode ray tube of a workstation for use with digital mammograms was calibrated with a photometer to produce an input-output characteristic curve similar to the perceptually linear curve defined by a current display standard. Then, a test pattern consisting of bars of increasing intensity containing disks of decreasing contrast was used by an observer to estimate the minimal detectable contrast (MDC) at different levels of display luminance. The MDC was modeled by a parabola. The shape of the parabola was determined by the observer's perceptual responses, and the range was determined by the maximum and minimum pixel values of the breast parenchyma. As each mammogram was displayed, the contour of the breast was automatically found and pixels within the breast image were sampled to determine the pixel values that were used to compute the maximum and minimum pixel values. The parabola was integrated to determine the look-up table for the initial MDC-tempered display of the mammogram. Preliminary observer performance tests showed no significant differences in the accuracy and speed of three radiologists who read a set of mammograms when the MDC-tempered display was compared with the perceptually linear display.

Index Terms: Breast, 00.99 • Images, display • Radiography, digital




This article has been cited by other articles:


Home page
RadiologyHome page
H. L. Kundel, C. F. Nodine, E. F. Conant, and S. P. Weinstein
Holistic Component of Image Perception in Mammogram Interpretation: Gaze-tracking Study
Radiology, February 1, 2007; 242(2): 396 - 402.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. F. Nodine, C. Mello-Thoms, S. P. Weinstein, H. L. Kundel, E. F. Conant, R. E. Heller-Savoy, S. E. Rowlings, and J. A. Birnbaum
Blinded Review of Retrospectively Visible Unreported Breast Cancers: An Eye-Position Analysis