RadioGraphics, Vol 17, 753-760, Copyright © 1997 by Radiological Society of North America
ARTICLES |
JA Rowlands, W Zhao, IM Blevis, DF Waechter and Z Huang
Imaging Research Program, Sunnybrook Health Science Centre, University of Toronto, Ontario, Canada.
Future imaging techniques will be capable of high image quality, fast acquisition, compactness, and versatile operation. A flat-panel imager that is expected to achieve these goals is under development. It consists of a thin layer of amorphous selenium that converts x rays directly to an electric charge and a thin-film electronic circuit, or active matrix, to read out the electronic signal directly to a computer host. The advantages of amorphous selenium include high resolution and low noise without loss of signal strength. The advantages of the active matrix are real-time readout, flexible design parameters, and compactness of the readout structures. A prototype of this imager has been built and operated, and initial images (of an x-ray test bar pattern and a hand phantom) have been acquired. Although the prototype was built to test scientific principles and many possibilities for optimization remain, the images already possess the quality necessary for many radiographic procedures. A large range of current and new applications exist for this imager.
This article has been cited by other articles:
![]() |
B. F. Branstetter IV Basics of Imaging Informatics: Part 2 Radiology, July 1, 2007; 244(1): 78 - 84. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Samei, J. Y. Lo, T. T. Yoshizumi, J. L. Jesneck, J. T. Dobbins II, C. E. Floyd Jr, H. P. McAdams, and C. E. Ravin Comparative Scatter and Dose Performance of Slot-Scan and Full-Field Digital Chest Radiography Systems Radiology, June 1, 2005; 235(3): 940 - 949. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Zahringer, V. Hesselmann, O. Schulte, K. F. Kamm, W. Braun, G. Haupt, B. Krug, and K. Lackner Reducing the Radiation Dose During Excretory Urography: Flat-Panel Silicon X-Ray Detector Versus Computed Radiography Am. J. Roentgenol., October 1, 2003; 181(4): 931 - 937. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Rapp-Bernhardt, F. W. Roehl, R. C. Gibbs, H. Schmidl, U. W. Krause, and T. M. Bernhardt Flat-Panel X-ray Detector Based on Amorphous Silicon versus Asymmetric Screen-Film System: Phantom Study of Dose Reduction and Depiction of Simulated Findings Radiology, May 1, 2003; 227(2): 484 - 492. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, H. J. Lee, M. J. Chung, J. B. Seo, H. Y. Kim, Y.-J. Lee, J.-W. Kang, and J. H. Kim Detection of Simulated Chest Lesions by Using Soft-Copy Reading: Comparison of an Amorphous Silicon Flat-Panel-Detector System and a Storage-Phosphor System Radiology, July 1, 2002; 224(1): 242 - 246. [Abstract] [Full Text] |
||||
![]() |
T. S. Kim, J.-G. Im, J. M. Goo, K. H. Lee, Y.-J. Lee, S. H. Kim, and S. Kim Detection of Pulmonary Edema in Pigs: Storage Phosphor versus Amorphous Selenium-based Flat-Panel-Detector Radiography Radiology, June 1, 2002; 223(3): 695 - 701. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, J. H. Kim, J. B. Seo, T. S. Kim, S. J. Shine, and W. Lee Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor System: Comparison of Soft-Copy Images Am. J. Roentgenol., October 1, 2000; 175(4): 1013 - 1018. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Garmer, S. P. Hennigs, H. J. Jager, F. Schrick, T. van de Loo, A. Jacobs, A. Hanusch, A. Christmann, and K. Mathias Digital Radiography Versus Conventional Radiography in Chest Imaging: Diagnostic Performance of a Large-Area Silicon Flat-Panel Detector in a Clinical CT-Controlled Study Am. J. Roentgenol., January 1, 2000; 174(1): 75 - 80. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOGRAPHICS | RADIOLOGY | RSNA JOURNALS ONLINE |