RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bick, U.
Right arrow Articles by Doi, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bick, U.
Right arrow Articles by Doi, K.

RadioGraphics, Vol 16, 1403-1411, Copyright © 1996 by Radiological Society of North America


ARTICLES

Density correction of peripheral breast tissue on digital mammograms

U Bick, ML Giger, RA Schmidt, RM Nishikawa and K Doi
Department of Radiology, University of Muenster, Germany.

When digital mammograms are viewed on video displays, evaluation of the skin and subcutaneous tissue is often difficult and may require special window settings. An algorithm has been developed for selective enhancement (ie, density correction) of the dark peripheral portions of the breast on mammograms. After an automated segmentation of the digital mammogram and identification of the skin line, a fitted enhancement curve is generated to selectively enhance all pixels within a certain distance from the skin to match the density of the center part of the breast. After enhancement, skin and breast parenchyma can be evaluated simultaneously without the need for different window settings. When tested on a set of 400 digitized mammograms, the density correction algorithm significantly (P < .0001) increased the maximum area of breast tissue visualized simultaneously at window width settings of 0.5-2.0 delta OD (optical density). Artifacts interfering with interpretation were observed in less than 1%. The algorithm for correcting the density of peripheral breast tissue substantially facilitates and improves the display of digital mammograms and thus will be a valuable component of an integrated workstation for computer- aided diagnosis in mammography.


This article has been cited by other articles:


Home page
RadiologyHome page
S. Suryanarayanan, A. Karellas, S. Vedantham, H. Ved, S. P. Baker, and C. J. D'Orsi
Flat-Panel Digital Mammography System: Contrast-Detail Comparison between Screen-Film Radiographs and Hard-Copy Images
Radiology, December 1, 2002; 225(3): 801 - 807.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
L Costaridou, P Sakellaropoulos, A P Stefanoyiannis, E Ungureanu, and G Panayiotakis
Quantifying image quality at breast periphery vs mammary gland in mammography using wavelet analysis
Br. J. Radiol., October 1, 2001; 74(886): 913 - 919.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOGRAPHICS RADIOLOGY RSNA JOURNALS ONLINE
Copyright © 1996 by the Radiological Society of North America.