RadioGraphics, Vol 15, 993-1000, Copyright © 1995 by Radiological Society of North America
ARTICLES |
LE Antonuk, J Yorkston, W Huang, JH Siewerdsen, JM Boudry, Y el-Mohri and MV Marx
Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor 48109, USA.
As part of the development necessary for implementing a fully digital radiology department, the authors have investigated thin-film photodiodes and transistors for use in new photoelectronic imaging devices. One such device, a large-area, flat-panel, amorphous silicon imaging array, has been developed and is currently being tested. The array has a format of 512 x 560 pixels, a pixel-to-pixel pitch of 450 microns, and an area of 230 x 252 mm2, making it the largest self- scanning, solid-state imaging array developed to date. The array is used in conjunction with an overlying x-ray converter. Although specifically designed for megavoltage imaging, the device can produce high-quality, low spatial resolution, diagnostic x-ray images. Qualitative comparisons of array images of anthropomorphic head, chest, and pelvic phantoms and a spatial resolution pattern suggest that much of the information content of the film images at low spatial resolution is present in the corresponding array images. Current trends in the development of large-area, flat-panel imaging technology hold the promise of higher resolution arrays in the near future.
This article has been cited by other articles:
![]() |
M. Korner, C. H. Weber, S. Wirth, K.-J. Pfeifer, M. F. Reiser, and M. Treitl Advances in Digital Radiography: Physical Principles and System Overview RadioGraphics, May 1, 2007; 27(3): 675 - 686. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Zahringer, V. Hesselmann, O. Schulte, K. F. Kamm, W. Braun, G. Haupt, B. Krug, and K. Lackner Reducing the Radiation Dose During Excretory Urography: Flat-Panel Silicon X-Ray Detector Versus Computed Radiography Am. J. Roentgenol., October 1, 2003; 181(4): 931 - 937. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Rapp-Bernhardt, F. W. Roehl, R. C. Gibbs, H. Schmidl, U. W. Krause, and T. M. Bernhardt Flat-Panel X-ray Detector Based on Amorphous Silicon versus Asymmetric Screen-Film System: Phantom Study of Dose Reduction and Depiction of Simulated Findings Radiology, May 1, 2003; 227(2): 484 - 492. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. I. Whyte, R. Crownover, M. J. Murphy, D. P. Martin, T. W. Rice, M. M. DeCamp Jr, R. Rodebaugh, M. S. Weinhous, and Q.-T. Le Stereotactic radiosurgery for lung tumors: preliminary report of a phase I trial Ann. Thorac. Surg., April 1, 2003; 75(4): 1097 - 1101. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Bashore, E. R. Bates, P. B. Berger, D. A. Clark, J. T. Cusma, G. J. Dehmer, M. J. Kern, W. K. Laskey, M. P. O'Laughlin, S. Oesterle, et al. American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on Cardiac Catheterization Laboratory Standards: A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents endorsed by the American Heart Association and the Diagnostic and Interventional Catheterization Committee of the Council on Clinical Cardiology of the AHA J. Am. Coll. Cardiol., June 15, 2001; 37(8): 2170 - 2214. [Full Text] [PDF] |
||||