RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Farria, D. M.
Right arrow Articles by DeBruhl, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Farria, D. M.
Right arrow Articles by DeBruhl, N.

RadioGraphics, Vol 14, 371-385, Copyright © 1994 by Radiological Society of North America


ARTICLES

Mammography quality assurance from A to Z [published erratum appears in Radiographics 1994 Jul;14(4):930]

DM Farria, LW Bassett, C Kimme-Smith and N DeBruhl
Iris Cantor Center for Breast Imaging, UCLA School of Medicine 90024- 6952.

Quality assurance (QA) refers to all planned, systematic activities that instill confidence that quality mammography is being performed. Quality control (QC) refers only to the technical aspects of the examination. Standardized labeling of mammograms and the format for mammographic reports are important parts of a QA program; recommendations for both have been published by the American College of Radiology. Minimum staff for a mammography service consists of a scheduler, technologist(s), medical physicist, and radiologist. The scheduler asks the patient questions to ensure that the appropriate examination is performed, gives the patient instructions, and asks the patient to complete a history questionnaire including a release form to obtain earlier mammograms. One certified, licensed technologist is designated to perform QC, which includes maintaining darkroom, screen, and view box cleanliness; reviewing processor performance, checked with sensitometer, densitometer, and phantom images; repeat analysis; analysis of fixative retained in film, darkroom fog, screen-film contact, and adequacy of compression; and visual inspection of equipment. A certified medical physicist performs equipment acceptance testing and annual QC visits thereafter. The radiologist oversees all aspects of the QA program, including selecting and regularly observing the technologists, selecting and meeting with the physicist, communicating results, ensuring patient follow-up, and assessing patient outcome data. The radiologist is ultimately responsible for image quality and the standard of patient care.


This article has been cited by other articles:


Home page
radtechHome page
J. MINIGH
Mammographic Film Artifacts.
Radiol. Technol., May 1, 2006; 77(5): 389M - 402M.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. D. Pisano, M. Schell, J. Rollins, C. B. Burns, B. Hall, Y. Lin, M. P. Braeuning, E. Burke, and J. Holliday
Has the Mammography Quality Standards Act Affected the Mammography Quality in North Carolina?
Am. J. Roentgenol., April 1, 2000; 174(4): 1089 - 1091.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. P. Hogge, C. H. Palmer, C. C. Muller, S. T. Little, D. C. Smith, P. P. Fatouros, and E. S. de Paredes
Quality Assurance in Mammography: Artifact Analysis
RadioGraphics, March 1, 1999; 19(2): 503 - 522.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOGRAPHICS RADIOLOGY RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.