RadioGraphics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barnes, G. T.
Right arrow Articles by Hendrick, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barnes, G. T.
Right arrow Articles by Hendrick, R. E.

RadioGraphics, Vol 14, 129-138, Copyright © 1994 by Radiological Society of North America


ARTICLES

Mammography accreditation and equipment performance

GT Barnes and RE Hendrick
Department of Radiology, University of Alabama Hospitals and Clinics, Birmingham 35233.

Not all sites performing mammography produce optimal images at acceptably low doses. To address this situation, a voluntary accreditation program was instituted through the American College of Radiology. Each site applying for accreditation completes a detailed questionnaire about facilities and equipment, personnel, and quality control. Each unit at each site is evaluated by a medical physicist for clinical and phantom image quality and for average glandular dose. Although a site is accredited for 3 years, the performance of each unit is audited annually. Of 11,162 units for which accreditation was sought, only 5,856 (68%) passed at the first attempt, with another 18% passing after reapplication. The major reason for failure was inadequate clinical images, followed by inadequate phantom images, both inadequate clinical and phantom images, and inadequate quality control records. In a performance audit of 20 new units, an average of 5.8 problems were encountered per unit, the majority of which adversely affected image quality. These results support the requirement of equipment performance audits and raise the question of whether similar problems exist in other areas of medical imaging.